Fix NoMetricValuesForInstance error
This patch set allows in case of NoMetricValuesForInstance exception to continue the flow of Workload Stabilization strategy instead of interrupting. Closes-Bug: #1640096 Change-Id: I2de22bb97defb9c34e409102d06846275793b80d
This commit is contained in:
@@ -27,7 +27,7 @@ from oslo_config import cfg
|
|||||||
from oslo_log import log
|
from oslo_log import log
|
||||||
import oslo_utils
|
import oslo_utils
|
||||||
|
|
||||||
from watcher._i18n import _LI, _
|
from watcher._i18n import _LI, _LW, _
|
||||||
from watcher.common import exception
|
from watcher.common import exception
|
||||||
from watcher.decision_engine.cluster.history import ceilometer as \
|
from watcher.decision_engine.cluster.history import ceilometer as \
|
||||||
ceilometer_cluster_history
|
ceilometer_cluster_history
|
||||||
@@ -200,8 +200,12 @@ class WorkloadStabilization(base.WorkloadStabilizationBaseStrategy):
|
|||||||
aggregate='min'
|
aggregate='min'
|
||||||
)
|
)
|
||||||
if avg_meter is None:
|
if avg_meter is None:
|
||||||
raise exception.NoMetricValuesForInstance(
|
LOG.warning(
|
||||||
resource_id=instance_uuid, metric_name=meter)
|
_LW("No values returned by %(resource_id)s "
|
||||||
|
"for %(metric_name)s") % dict(
|
||||||
|
resource_id=instance_uuid,
|
||||||
|
metric_name=meter))
|
||||||
|
avg_meter = 0
|
||||||
if meter == 'cpu_util':
|
if meter == 'cpu_util':
|
||||||
avg_meter /= float(100)
|
avg_meter /= float(100)
|
||||||
instance_load[meter] = avg_meter
|
instance_load[meter] = avg_meter
|
||||||
|
|||||||
Reference in New Issue