Merge "Add gnocchi support in outlet_temp_control strategy"
This commit is contained in:
@@ -28,11 +28,14 @@ Outlet (Exhaust Air) Temperature is one of the important thermal
|
||||
telemetries to measure thermal/workload status of server.
|
||||
"""
|
||||
|
||||
import datetime
|
||||
|
||||
from oslo_log import log
|
||||
|
||||
from watcher._i18n import _
|
||||
from watcher.common import exception as wexc
|
||||
from watcher.datasource import ceilometer as ceil
|
||||
from watcher.datasource import gnocchi as gnoc
|
||||
from watcher.decision_engine.model import element
|
||||
from watcher.decision_engine.strategy.strategies import base
|
||||
|
||||
@@ -71,9 +74,15 @@ class OutletTempControl(base.ThermalOptimizationBaseStrategy):
|
||||
""" # noqa
|
||||
|
||||
# The meter to report outlet temperature in ceilometer
|
||||
METER_NAME = "hardware.ipmi.node.outlet_temperature"
|
||||
MIGRATION = "migrate"
|
||||
|
||||
METRIC_NAMES = dict(
|
||||
ceilometer=dict(
|
||||
host_outlet_temp='hardware.ipmi.node.outlet_temperature'),
|
||||
gnocchi=dict(
|
||||
host_outlet_temp='hardware.ipmi.node.outlet_temperature'),
|
||||
)
|
||||
|
||||
def __init__(self, config, osc=None):
|
||||
"""Outlet temperature control using live migration
|
||||
|
||||
@@ -83,8 +92,8 @@ class OutletTempControl(base.ThermalOptimizationBaseStrategy):
|
||||
:type osc: :py:class:`~.OpenStackClients` instance, optional
|
||||
"""
|
||||
super(OutletTempControl, self).__init__(config, osc)
|
||||
self._meter = self.METER_NAME
|
||||
self._ceilometer = None
|
||||
self._gnocchi = None
|
||||
|
||||
@classmethod
|
||||
def get_name(cls):
|
||||
@@ -118,6 +127,12 @@ class OutletTempControl(base.ThermalOptimizationBaseStrategy):
|
||||
"type": "number",
|
||||
"default": 30
|
||||
},
|
||||
"granularity": {
|
||||
"description": "The time between two measures in an "
|
||||
"aggregated timeseries of a metric.",
|
||||
"type": "number",
|
||||
"default": 300
|
||||
},
|
||||
},
|
||||
}
|
||||
|
||||
@@ -131,6 +146,20 @@ class OutletTempControl(base.ThermalOptimizationBaseStrategy):
|
||||
def ceilometer(self, c):
|
||||
self._ceilometer = c
|
||||
|
||||
@property
|
||||
def gnocchi(self):
|
||||
if self._gnocchi is None:
|
||||
self._gnocchi = gnoc.GnocchiHelper(osc=self.osc)
|
||||
return self._gnocchi
|
||||
|
||||
@gnocchi.setter
|
||||
def gnocchi(self, g):
|
||||
self._gnocchi = g
|
||||
|
||||
@property
|
||||
def granularity(self):
|
||||
return self.input_parameters.get('granularity', 300)
|
||||
|
||||
def calc_used_resource(self, node):
|
||||
"""Calculate the used vcpus, memory and disk based on VM flavors"""
|
||||
instances = self.compute_model.get_node_instances(node)
|
||||
@@ -153,14 +182,31 @@ class OutletTempControl(base.ThermalOptimizationBaseStrategy):
|
||||
|
||||
hosts_need_release = []
|
||||
hosts_target = []
|
||||
metric_name = self.METRIC_NAMES[
|
||||
self.config.datasource]['host_outlet_temp']
|
||||
for node in nodes.values():
|
||||
resource_id = node.uuid
|
||||
outlet_temp = None
|
||||
|
||||
outlet_temp = self.ceilometer.statistic_aggregation(
|
||||
resource_id=resource_id,
|
||||
meter_name=self._meter,
|
||||
period=self.period,
|
||||
aggregate='avg')
|
||||
if self.config.datasource == "ceilometer":
|
||||
outlet_temp = self.ceilometer.statistic_aggregation(
|
||||
resource_id=resource_id,
|
||||
meter_name=metric_name,
|
||||
period=self.period,
|
||||
aggregate='avg'
|
||||
)
|
||||
elif self.config.datasource == "gnocchi":
|
||||
stop_time = datetime.datetime.utcnow()
|
||||
start_time = stop_time - datetime.timedelta(
|
||||
seconds=int(self.period))
|
||||
outlet_temp = self.gnocchi.statistic_aggregation(
|
||||
resource_id=resource_id,
|
||||
metric=metric_name,
|
||||
granularity=self.granularity,
|
||||
start_time=start_time,
|
||||
stop_time=stop_time,
|
||||
aggregation='mean'
|
||||
)
|
||||
# some hosts may not have outlet temp meters, remove from target
|
||||
if outlet_temp is None:
|
||||
LOG.warning("%s: no outlet temp data", resource_id)
|
||||
|
||||
Reference in New Issue